vyhledávání
Produkty
Speciální nabídka

Lenovo Storage V5030 SFF Control Enclosure

Kalkulačka splátek CETELEM
1368776 Kč s DPH

1131220 Kč bez DPH
Dostupnost: Nedostupné
Part no.: 6536C22
Výrobce: LENOVO
Váha: 28,3
Záruka: 36 měsíců
Lenovo Storage V5030 SFF Control Enclosure
Produkt je zařazen:

Popis produktu:
Lenovo Storage V5030 (Machine Type 6536) is a highly flexible, easy to use virtualized storage system that enables midsize organizations to meet the challenges of rapid data growth and limited IT budgets. By using Spectrum Virtualize software functions, interoperability, and management tools, Lenovo Storage V5030 enables organizations to consolidate and provide new capabilities to their infrastructures. Lenovo Storage V5030 control enclosure models include two node canisters, each with 16 GB cache upgradeable to 32 GB per canister for a system total of 64 GB cache. A 1 Gb iSCSI connectivity is standard, with an option for additional 1 Gb iSCSI, 12 Gb SAS, 16 Gb Fibre Channel (FC), or 10 Gb iSCSI or Fibre Channel over Ethernet (FCoE) connectivity.
A Lenovo Storage V5030 system scales up to 504 drives with the attachment of up to 20 Lenovo Storage V5030 expansion enclosures. It also offers flexible drive configurations with the choice of 2.5-inch and 3.5-inch form factors, 10 K or 15 K rpm SAS and 7.2 K rpm NL SAS hard disk drives (HDDs), and SAS flash drives (solid-state drives [SSDs]).


Form factor
•Lenovo Storage V5030 control enclosure: 2U rack mount
•Lenovo Storage V5030 expansion enclosure: 2U rack mount

Controller configuration
Dual controller (known as node canister) configuration per control enclosure. Two control enclosures can be combined into a single clustered system (or cluster).

RAID levels
RAID 0, 1, 5, 6, and 10; Distributed RAID 5 and 6 (internal storage only).

Controller cache
32 GB per system (16 GB per node canister) upgradeable to 64 GB (32 GB per node canister). Cache mirroring between the node canisters. Battery-backed cache protection.

Drive bays
Up to 504 SFF drive bays per single system (up to 1,008 SFF drive bays per cluster): •24 SFF drive bays in the control enclosure •24 SFF drive bays in the expansion enclosure; up to 20 expansion enclosures
Up to 252 LFF drive bays per single system (up to 504 LFF drive bays per cluster): •12 LFF drive bays in the control enclosure •12 LFF drive bays in the expansion enclosure; up to 20 expansion enclosures
Intermix of SFF and LFF enclosures is supported.

Drive technology
SAS and NL SAS HDDs and SAS SSDs. Intermix of HDDs and SSDs is supported.

Drive connectivity
Dual-ported 12 Gb SAS drive attachment infrastructure.
Control enclosure with two node canisters (ports per one node canister): •24x 12 Gb SAS internal drive ports (SFF chassis) •12x 12 Gb SAS internal drive ports (LFF chassis) •2x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion ports for the attachment of the expansion enclosures
Expansion enclosure with two expansion canisters (ports per one expansion canister): •24x 12 Gb SAS internal drive ports (SFF chassis) •12x 12 Gb SAS internal drive ports (LFF chassis) •2x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion ports (IN and OUT) for the daisy chained attachment of the expansion enclosures

Drives
SFF drives: •300 GB and 600 GB 15K rpm SAS HDDs •900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs •2 TB 7.2K rpm NL SAS HDDs •400 GB, 800 GB, 1.6 TB, and 3.2 TB SAS SSDs
LFF drives: •300 GB and 600 GB 15K rpm SAS HDDs •900 GB, 1.2 TB, and 1.8 GB 10K rpm SAS HDDs •4 TB, 6 TB, and 8 TB 7.2K rpm NL SAS HDDs

Storage capacity
•Up to 2.016 PB (252x 8 TB NL SAS HDDs) per single system
•Up to 4.032 PB (504x 8 TB NL SAS HDDs) per cluster

Host connectivity Standard ports (per control enclosure with two node canisters):
•4x 1 Gb iSCSI host ports (UTP, RJ-45) (2 ports per node canister)
Optional additional ports on host interface cards (per control enclosure with two node canisters):
•8x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644) (4 ports per node canister)
•8x 1Gb iSCSI host ports (UTP, RJ-45) (4 ports per node canister)
•8x 10 Gb iSCSI or FCoE SFP+ host ports (SW fiber, LC) (4 ports per node canister)
•8x 16 Gb FC SFP+ host ports (SW or LW fiber, LC) (4 ports per node canister)

Host operating systems
Microsoft Windows Server 2012 and 2012 R2; Red Hat Enterprise Linux (RHEL) 6 and 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere 5.1, 5.5, and 6.0.

Standard software features
Virtualization of internal storage, Thin Provisioning, One-way Data Migration, Dual-system Clustering, HyperSwap (requires a Remote Mirroring license), and Embedded GUI.

Optional software features
Easy Tier, FlashCopy, Real-time Compression, Encryption, Remote Mirroring, and External Virtualization.

Performance (single system)
•Up to 730,000 cache read IOPS •Up to 205,000 disk read IOPS •Up to 51,000 disk write IOPS •Up to 112,000 disk mixed (70% read/30% write) IOPS •Up to 8.3 GBps sequential disk read throughput •Up to 3.5 GBps sequential disk write throughput

Configuration maximums
Per one control enclosure / cluster (if different): •Maximum storage capacity (including virtualized external storage): 32 PB •Maximum number of storage pools: 1,024 •Maximum number of logical volumes: 2,048 / 4,096 •Maximum logical volume size: 256 TB •Maximum number of drives in a RAID array: 16 •Maximum number of RAID arrays: 128 •Maximum number of drives in a distributed RAID array: 128 (including up to 4 spares) •Maximum number of distributed RAID arrays: 10 / 20 •Maximum hot spare drives: No limit •Maximum number of host ports: 2,048 / 4,096 •Maximum number of hosts: 256 / 512 •Maximum number of host ports per one host: 32 •Maximum number of snapshots: 2,048 / 4,096 (requires an optional license) •Maximum number of remote mirroring relationships: 2,048 / 4,096 (requires an optional license)

Cooling
Redundant cooling with the fan modules that are built into power supplies.

Power supply
Two redundant hot-swap 800 W AC power supplies.

Hot-swap parts
Node canisters, expansion canisters, SFP+ transceivers, drives, power supplies with fans.

Management interfaces
2x 1 GbE ports (UTP, RJ-45) in a primary/redundant configuration. Web-based GUI; SSH CLI; SMI-S; SNMP and email notifications.

Security features
Secure Socket Layer (SSL), Secure Shell (SSH), user level security, LDAP authentication.

Hardware warranty
Three-year customer-replaceable unit and onsite warranty with 9x5 next business day terms. Optional warranty service upgrades are available through Lenovo: 24x7 coverage, 2-hour or 4-hour response time, 6-hour or 24-hour committed repair, 1-year or 2-year warranty extensions, Hard Drive Retention.

Software maintenance
Three-year or five-year (model dependent) base software maintenance is included. Models with five-year software maintenance require additional two years of hardware support be purchased for the model.

Dimensions
Height: 87 mm (3.4 in); width: 483 mm (19.0 in); depth: 556 mm (21.9 in) Weight •Control enclosure (fully configured): 27.7 kg (61.1 lb) •Expansion enclosure (fully configured): 26.7 kg (58.9 lb)



Lenovo Press - https://lenovopress.com/lp0498-lenovo-storage-v5030


Přes veškerou snahu zajistit co nejpřesnější popis a technické parametry produktů nemůžeme zaručit, že uváděná data odpovídají skutečnosti. Řada výrobců si vyhrazuje právo změny některých parametrů či vlastností bez předchozího upozornění. Potřebujete-li ujištění o určitých parametrech produktu nebo v případě pochybností, kontaktujte prosím svého obchodníka. Pozdější reklamace vlastností je zbytečnou komplikací pro obě strany.


Diskuze k Lenovo Storage V5030 SFF Control Enclosure
Diskuze k produktu: lenovo-storage-v5030-sff-control-enclosure není založena. Pokud chcete vložit nový příspěvek, je třeba se přihlásit nebo zaregistrovat.
Pokud chcete sledovat diskuzi emailem, je třeba se přihlásit nebo zaregistrovat.